K Microelettrica Catalogue | Mobility | Products | Components | Railway Contactors | LTC Series
LTC Series
LTC Line contactors are our compact device solution. They are small, powerful and safe, applicable to both rail and industrial markets in the most severe applications.
Thanks to our long production history, we can offer many configurations to cover all customer needs.
- Ratings up to 4000 VDC/AC and up to 1100 A/pole applications
- Multi-pole combination up to 4 poles
- NO and NC poles
- Category / Operational Frequency class : A2 / C3
- Designed for applications up to OV3, PD3
- According to the blow-out system, suitable for DC uni- directional, DC bi-directional, or AC currents
- Equipped with low voltage spike protection
- Vertical or horizontal mounting
- Suitable for low current interruption
- IEC60077 and IEC60947-4-1 compliant
- Offered in 5 standard sizes to fit any requirements with the minimum required dimensions.
- Series or parallel connections on bipolar contactors to minimize space requirement.
- Permanent magnets for quickest switching with unidirectional low DC and any AC currents, reduced dimensions and weight.
- Highest compactness guaranteed with plastic arc-chute
- Main contacts with silver alloy tips
- Control voltage: 24 – 36 – 48 – 72 – 110 VDC
- DC coil supply with 6.35×0.8 mm Fast-on terminals
- 2 NO + 2 NC auxiliary contact blocks, 6.35×0.8 mm Fast-on terminals
- Voltage suppressor on LV coil (Varistor)
- Main contacts with Ag/C alloy tips
- Supply system with mechanical latch
- Control voltage: from 12 to 440 VDC/AC
- Up to 4 auxiliary contacts blocks
- 1 NO + 1 NC / 2 NO versions
- Gold plated tips (for extremely low currents)
- Screw terminals
- Low voltage connectors (all brands available)
- Alternative Voltage suppressor on LV coil (Diode + Transzorb)
Series Size Poles |
LTCH 60 1NO | 2NO | |
LTC 100 1NO* | 2NO | |
LTCS 250 1NO* | 2NOs* | 2NOp* | 3NO | 4NO | | | | |
LTCH 250 1NO* | 2NOs* | 2NOp* | 3NO | 4NO | | | | |
LTCS 300 1NO | 2NOs* | 2NOp* | 3NO | 4NO | | | | |
LTCH 300 1NO | 2NOs* | 2NOp* | 3NO | 4NO | | | | |
LTCH 1000 1NO |
||
Application Type | Precharge Contactor | Precharge Contactor Battery Charger Output Contactor Capacitor Discharge Contactor |
Precharge Contactor AUX Input Contactor AUX Output Contactor Battery Charger Input Contactor Battery Charger Output Contactor Capacitor Discharge Contactor Heater Contactor |
Precharge Contactor AUX Input Contactor AUX Output Contactor Battery Charger Input Contactor Capacitor Discharge Contactor Heater Contactor |
Precharge Contactor AUX Input Contactor AUX Output Contactor Battery Charger Input Contactor Battery Charger Output Contactor Heater Contactor |
Precharge Contactor AUX Input Contactor AUX Output Contactor Battery Charger Input Contactor Heater Contactor |
Line Contactor DC/DC Converter Input Contactor Coach Power Supply Contactor |
||
Rated Operational Voltage (up to) |
[V] | 3600 | 900 | 1800 | 1800 | 1800 | 1800 | 1800 | |
Thermal Current @ 75°C ** | [A] | 50 | 80 | 200 | 200 | 270 | 270 | 1000 | |
Short Circuit Withstand Current for 5ms |
[kA] | 2 | 1.5 | 5 | 5 | 5 | 5 | 20 | |
DC Rated Operational Current (L/R=15 ms) *** |
440 Vdc | [A] | - | 40 | 130 | 200 | 130 | 200 | - |
900 Vdc | [A] | 80 | 16 | 65 | 100 | 65 | 100 | 1200 | |
1800 Vdc | [A] | 40 | - | 16 | 20 | 16 | 20 | 600 | |
3600 Vdc | [A] | 16 | - | - | - | - | - | - | |
DC Max Breaking Current (L/R=5 ms) *** |
440 Vdc | [A] | - | 60 | 195 | 225 | 195 | 225 | - |
900 Vdc | [A] | 120 | 25 | 130 | 150 | 130 | 150 | 3200 | |
1800 Vdc | [A] | 60 | - | 25 | 30 | 25 | 30 | 1600 | |
3600 Vdc | [A] | 30 | - | - | - | - | - | - | |
AC Rated Operational Current (cosphi = 0.8) *** |
440 Vac | [A] | - | 40 | 130 | 200 | 130 | 200 | - |
900 Vac | [A] | 80 | 16 | 65 | 100 | 65 | 100 | 1200 | |
1800 Vac | [A] | 40 | - | 16 | 20 | 16 | 20 | 600 | |
3600 Vac | [A] | 16 | - | - | - | - | - | - | |
AC Max Breaking Current (cosphi = 0.8) *** |
440 Vac | [A] | - | 80 | 320 | 400 | 320 | 400 | - |
900 Vac | [A] | 200 | 40 | 160 | 200 | 160 | 200 | 3200 | |
1800 Vac | [A] | 100 | - | 80 | 100 | 80 | 100 | 1600 | |
3600 Vac | [A] | 50 | - | - | - | - | - | - | |
Dimensions | Length L | [mm] | 170 | 170 | 105 | 120 | 140 | 140 | 140 | 140 | 140 | 155 | 155 | 155 | 155 | 155 | 140 | 140 | 140 | 140 | 140 | 155 | 155 | 155 | 155 | 385 |
Width W | [mm] | 80 | 150 | 65 | 100 | 90 | 110 | 110 | 170 | 220 | 90 | 110 | 110 | 170 | 220 | 90 | 110 | 110 | 170 | 220 | 90 | 110 | 110 | 170 | 220 | 94 | |
Height H | [mm] | 240 | 220 | 130 | 155 | 160 | 160 | 160 | 160 | 160 | 180 | 180 | 180 | 180 | 180 | 160 | 160 | 160 | 160 | 160 | 180 | 180 | 180 | 180 | 180 | 300 | |
Weight | [kg] | 3 | 4 | 1.1 | 2 | 2 | 3.5 | 3.5 | 5 | 6.5 | 2.2 | 4.1 | 4.1 | 5.9 | 7.7 | 2 | 3.5 | 3.5 | 5 | 6.5 | 2.2 | 4.1 | 4.1 | 5.9 | 7.7 | 9.9 |
* Normally Closed (NC) poles are available. For further information please contact us
** for higher thermal current please check parallel configurations (“2NOp” datasheet)
*** for higher values please check series configurations (“2NOs” datasheet)