Heater contactor

Heater contactor

Heater contactors manage the duty cycle of heaters, by switching them on and off according to a variable pattern related to the heat demand. Heating systems are supplied with high voltage, typically 3kV DC or 1kV AC (supplied by a secondary winding of the main transformer).

This application requires a challenging combination of high thermal current and electrical durability. We offer a wide variety of designs to fit most installation requirements.

  • High making and breaking capability
  • Suitable for heavy-duty electrical and mechanical operating conditions
Image Image Image Image Image Image
Series
Size
Poles


LTCS
250
1NO

LTCH
250
1NO

LTCS
300
1NO

LTCH
300
1NO

LTHS
320
1NO

LTHH
100
1NO

Rated Operational Voltage
(up to)
[V] 1800 1800 1800 1800 1800 3600
Thermal Current @ 75°C [A] 200 200 270 270 320 100
Short Circuit Withstand Current for 5ms [kA] 5 5 5 5 8 4
Fault Making Capacity [kA] 2.4 2.4 2.4 2.4 4.8 2.4
DC
Rated Operational Current
(L/R=15 ms)
900 Vdc [A] 65 100 65 100 300 460
1800 Vdc [A] 16 20 16 20 150 230
3600 Vdc [A] - - - - - 110
DC
Max Breaking Current
(L/R=5 ms)
900 Vdc [A] 130 150 130 150 750 500
1800 Vdc [A] 25 30 25 30 275 250
3600 Vdc [A] - - - - - 125
AC
Rated Operational Current
(cosphi = 0.8)
900 Vac [A] 65 100 65 100 300 460
1800 Vac [A] 16 20 16 20 150 230
3600 Vac [A] - - - - - 110
AC
Max Breaking Current
(cosphi = 0.8)
900 Vac [A] 160 200 160 200 750 660
1800 Vac [A] 80 100 80 100 275 360
3600 Vac [A] - - - - - 180
Dimensions Length L [mm] 140 154 140 154 221 377
Width W [mm] 89 89 89 89 86 60
Height H [mm] 157 177 157 177 301 274