K Microelettrica Catalogue | Mobility | Products | Components | Railway Contactors | LTHH/LTE/LTP Series
LTHH/LTE/LTP Series
LTHH Line contactors are the perfect solution for application in 4kV systems, applied to both on board and fixed installations in rail applications.
Our product line provides a wide current range and high reliability. Thanks to the thin design and the single-side layout of power terminals, we reduce the device size and ensure easier operations.
Thanks to our yearlong experience, we can offer many configurations to cover all customer needs.
- Ratings up to 4000 VDC/AC and up to 1350 A/pole applications
- Multi-pole combination up to 3 poles
- NO and NC poles
- Category / Operational Frequency class : A2 / C3
- Designed for applications up to OV3, PD3
- Suitable for bi-directional DC or AC currents
- Equipped with low voltage spike protection
- Vertical or horizontal mounting
- Suitable for low current interruption
- IEC60077 compliant
- Offered in 8 standard sizes to fit any requirements with the minimum required dimensions
- Pneumatic operation version available on request
- Configurable according customer needs
- Customizable breaking system tailored for any service condition (out of standards)
- High electrical durability guaranteed with ceramic arc-chute
- DC coil controlled with power saving system
- Coil operated version
- Arc-extinguishing system with indirect blow-out coil with or without arcing contacts
- DC coil supply with 6.35×0.8 mm Fast-on terminals
- Control voltage: 24 – 36 – 48 – 72 – 110 VDC
- 2 NO + 2 NC auxiliary contact blocks, 6.35×0.8 mm Fast-on terminals
- Voltage suppressor on LV coil (Varistor)
- Pneumatic operated version
- Arc-extinguishing system with: (*)
- Indirect blow-out coil and arcing contacts
- Direct blow-out coil
- Control voltage: from 12 to 240 VDC/AC
- Up to 4 auxiliary contacts blocks
- 1 NO + 1 NC / 2 NO versions
- Gold plated tips (for extremely low currents)
- Screw terminals
- Low voltage connectors (all brands available)
- Alternative Voltage suppressor on LV coil (Diode + Transzorb)
(*) We recommend these versions for applications where high voltage breaking performance and DC low current are foreseen, especially in case of changes in breaking current direction.
Please contacts us to discuss specific application requirements.
Series Size Poles |
LTHH 40 1NO |
LTHH 100 1NO *** |
LTHH 250* 1NO |
LTHH 400* 1NO |
LTE 2-600** 1NO |
LTE 4-400** 1NO |
LTE 4-600** 1NO |
LTE 4-2000** 1NO |
||
Application Type | Precharge Contactor Line Test Contactor |
Precharge Contactor Line Contactor AUX Input Contactor Battery Charger Input Contactor DC/DC Converter Input Contactor Capacitor Discharge Contactor Heater Contactor Line Test Contactor |
Line Contactor AUX Input Contactor Battery Charger Input Contactor DC/DC Converter Input Contactor Coach Power Supply Contactor Line Test Contactor |
Line Contactor DC/DC Converter Input Contactor Coach Power Supply Contactor |
Line Contactor DC/DC Converter Input Contactor Coach Power Supply Contactor |
Line Contactor DC/DC Converter Input Contactor Coach Power Supply Contactor |
Line Contactor DC/DC Converter Input Contactor Coach Power Supply Contactor |
Line Contactor DC/DC Converter Input Contactor Coach Power Supply Contactor |
||
Rated Operational Voltage (up to) |
[V] | 1800 | 3600 | 3600 | 3600 | 1800 | 3600 | 3600 | 3600 | |
Thermal Current @ 75°C |
[A] | 40 | 100 | 250 | 400 | 800 | 800 | 800 | 1300 | |
Short Circuit Withstand Current for 5ms |
[kA] | 2 | 4 | 6 | 8 | 16 | 16 | 16 | 45 | |
DC Rated Operational Current (L/R=15 ms) |
900 Vdc | [A] | 100 | 460 | 900 | 900 | 1050 | 1125 | 1540 | 1540 |
1800 Vdc | [A] | 50 | 230 | 450 | 450 | 500 | 750 | 1050 | 1400 | |
3600 Vdc | [A] | - | 110 | 270 | 270 | - | 330 | 500 | 650 | |
DC Max Breaking Current (L/R=5 ms) |
900 Vdc | [A] | 115 | 500 | 1160 | 1160 | 1400 | 1620 | 1750 | 1750 |
1800 Vdc | [A] | 60 | 250 | 580 | 580 | 650 | 1080 | 1400 | 1750 | |
3600 Vdc | [A] | - | 125 | 400 | 400 | - | 500 | 650 | 830 | |
AC Rated Operational Current (cosphi = 0.8) |
900 Vac | [A] | 100 | 460 | 900 | 900 | 1050 | 1125 | 1540 | 1540 |
1800 Vac | [A] | 50 | 230 | 450 | 450 | 500 | 750 | 1050 | 1400 | |
3600 Vac | [A] | - | 110 | 270 | 270 | - | 330 | 500 | 650 | |
AC Max Breaking Current (cosphi = 0.8) |
900 Vac | [A] | 160 | 660 | 1160 | 1160 | 1900 | 2000 | 2200 | 3000 |
1800 Vac | [A] | 80 | 360 | 800 | 800 | 1000 | 1500 | 1900 | 2500 | |
3600 Vac | [A] | - | 180 | 400 | 400 | - | 800 | 1000 | 1200 | |
Dimensions | Length L | [mm] | 200 | 377 | 381 | 381 | 430 | 430 | 430 | 501 |
Width W | [mm] | 48 | 60 | 72 | 70 | 80 | 85 | 85 | 119 | |
Height H | [mm] | 163 | 274 | 331 | 332 | 370 | 394 | 423 | 473 | |
Weight | [kg] | 1.8 | 6.5 | 8.5 | 9 | 13 | 13 | 13.3 | 28 |
* Only with special arc chute
** Available with electro-pneumatic actuating system
*** Normally Closed (NC) pole is available. For further information please contact us