K Microelettrica Catalogue | Mobility | Products | Components | Disconnectors | Isolation and Changeover | LTHM/P-U/D Series
LTHM/P-U/D Series
LTHM/P-U/D Line disconnectors feature a modular design to support any combinations of max 4 NO, NC and CO poles with electric motor or pneumatic control. The poles may be connected in parallel for higher current ratings. The short circuit withstanding capability is exceptional (> 140 kA).
- Ratings up to 4000 VDC/AC and up to 3000 A/pole applications
- Single pole or Change over Disconnector
- Modular-Multipolar up to 4 poles
- Category / Operational Frequency class : A4 / C3
- Designed for applications up to OV3, PD3
- Main terminals positions: D, U, DC or CO type
- IEC60077 compliant
- Well-known extra heavy duty line for up to 4 kV systems
- LTHM Line power connection layouts:
- D version (IN and OUT on opposite sides) for NO, NC or CO type, up to 4 poles
- U version (IN and OUT on the same side) for NO or NC poles, up to 2 poles
- DC version (IN and OUT on the same side, one above the other) for NO and NC poles, up to 4 poles
- CO version (IN and first OUT on the same side, second OUT on the opposite side) for NO and NC poles, up to 4 poles
- Up to 4 poles: 800A or 1500A rated. Every pole may have 1 NO or 1 NO+1 NC, or 1 CO contacts.
- The contact technology, based on multi-finger jaws, enables LTMH line disconnectors to withstand the worst dynamic currents foreseen in railway and industry applications.
- Electric contacts based on LTHM/LTHP concept, providing exceptional short circuit capability, up to 180 kA
- Most compact design can provide size, weight and cost optimization
- Motorized operated version
- Bistable version, 2-position command relays
- Control voltage: 24 – 36 – 48 – 72 – 110 VDC
- Aux contacts: 2 NO + 2NC
- SMS24 low voltage connector
- Pneumatic operated version
- Control voltage: from 12 to 220 VDC
- Monostable version, 1-position command relays
- Low voltage connectors (all brands available)
Series Size Poles |
LTHMD 800 1NO | 2NO | 3NO | 4NO | | | |
LTHMU 800 1NO | 2NO | |
LTHMD 800 1 CO | 2 CO | 3CO | 4CO | | | |
LTHMD 1500 1NO | 2NO | 3NO | 4NO | | | |
LTHMU 1500 1NO | 2NO | |
LTHMD 1500 1CO | 2CO | 3CO | | |
LTHMD 3000 1NO | 1CO | 2NO | 2CO | | | |
||
Application Type | Multisystem Vehicle Configurator Inverter Isolation Alternator-Rectifier Disconnector Roof Disconnector |
Multisystem Vehicle Configurator Inverter Isolation Alternator-Rectifier Disconnector Roof Disconnector |
Multisystem Vehicle Configurator Inverter Isolation Alternator-Rectifier Disconnector Roof Disconnector |
Multisystem Vehicle Configurator Inverter Isolation Alternator-Rectifier Disconnector Roof Disconnector |
Multisystem Vehicle Configurator Inverter Isolation Alternator-Rectifier Disconnector Roof Disconnector |
Multisystem Vehicle Configurator Inverter Isolation Alternator-Rectifier Disconnector Roof Disconnector |
Multisystem Vehicle Configurator Inverter Isolation Alternator-Rectifier Disconnector Roof Disconnector |
||
Rated Insulation Voltage @ OV3/PD3 |
[V] | 4000 | 4000 | 4000 | 4000 | 4000 | 4000 | 4000 | |
Thermal Current @ 75°C | [A] | 720 | 720 | 720 | 1350 | 1350 | 1350 | 2700 | |
Short Circuit Withstand Current for 5ms |
[kA] | 90 | 90 | 90 | 140 | 140 | 100 | 140 | |
Dimensions | Length L | [mm] | 450 | 560 | 560 | 560 | 442 | 445 | 445 | 498 | 560 | 560 | 445 | 560 | 560 | 560 | 441 | 445 | 445 | 498 | 560 | 447 | 477 | 560 | 501 |
Width W | [mm] | 140 | 177 | 235 | 293 | 173 | 240 | 142 | 178 | 236 | 289 | 140 | 178 | 235 | 293 | 173 | 240 | 140 | 178 | 236 | 177 | 177 | 294 | 294 | |
Height H | [mm] | 255 | 288 | 288 | 288 | 268 | 302 | 366 | 366 | 366 | 257 | 288 | 288 | 288 | 268 | 302 | 366 | 366 | 253 | 314| 288 | 366 | |
Weight | [kg] | 8.6 | 12.4 | 16.8 | 20.6 | 10.5 | 18.4 | 11 | 16 | 21 | 26 | 9.8 | 15 | 20.2 | 25.4 | 11 | 18.5 | 11 | 18.2 | 26 | 14 | 18 | 35 | 43 |