Line test contactor

Line test contactor

Powering up a high voltage rail circuit can lead to a short circuit. The Line Test Contactor reduces the making current by inserting the line test resistor in series to the load for a few seconds. The supervision system measures the making current to check the circuit status. If conditions are safe, the system closes the high-speed circuit breaker and opens the line test contactor.

We offer a wide variety of designs fitting most installation requirements.

  • High making current capability through special contact tips
  • Compact size
Image Image Image Image
Series
Size
Poles


LTHH
40
1NO

LTCH
250
1NO | 2NOs

|
LTHH
100
1NO

LTHH
250
1NO*

Rated Operational Voltage
(up to)
[V] 1800 1800 3600 3600
Thermal Current @ 75°C [A] 40 200 100 250
Short Circuit Withstand Current for 5ms [kA] 2 5 4 6
Fault Making Capacity [kA] 1.2 2.4 2.4 3.6
DC Rated Operational Current (L/R=15 ms) 900 Vdc [A] 100 100 | 300 460 900
1800 Vdc [A] 50 20 | 150 230 450
3600 Vdc [A] - - 110 270
DC Max Breaking Current (L/R=5 ms) 900 Vdc [A] 115 150 | 500 500 1160
1800 Vdc [A] 60 30 | 250 250 580
3600 Vdc [A] - - 125 400
Dimensions Length L [mm] 200 155 | 155 377 381
Width W [mm] 48 90 | 110 60 72
Height H [mm] 163 180 | 180 274 331
Weight [kg] 1.8 2.2 | 4.1 6.5 8.5

*Only with special arc chute