IFU Series

IFU units are a solution we propose to integrate some elementary train functions into a single product. We can in fact supply contactors, disconnectors, current sensors, and resistors assembled in the same structure. Our IFU units can be a combination of our own products and other components you can specify.

  • Ratings up to 4000 VDC/AC and up to 3000 A applications
  • Plug & Play approach
  • Equipped with a unique low-voltage connector
  • Easier for you to specify and integrate, while internal design is in our scope
  • Easier to install and maintain, with reduced mechanical and electrical interfaces
  • Compact solution guaranteed, based on our deep components knowledge
  • Easier to test: we perform routine tests for the entire IFU functions, considering all mutual interactions
  • Easier access to technical information in the documentation that we provide

IFU is a 100% customized product. On the same baseplate, it can implement at least two of the followings:

  • Line contactor
  • Pre-charge contactor
  • Pre-charge Resistor
  • Discharge contactor
  • Change-over switch for Output transformer configurator
  • Change-over switch for Auxiliary converter configuration
  • Current Transducer
Image Image Image
LPC1000

LPRC1000

LRU

Function [A] Line
Contactor
Precharge Line
Contactor
Precharge
Contactor
Resistor Line
Contactor
Precharge
Contactor
Discharge
contactor
Precharge
Resistor
(optional)
Discharge
Resistor
(optional)
Changevover
disconnector
(optional)
Current
sensor
(optional)
Thermal Current @ 75°C [A] 1000 50 1000 50 - up to 1600 up to 300 up to 300 - - up to 3000 -
Short circuit
withstand current for 5ms
[kA] 20 1 20 1 - up to 20 ut to 5 ut to 5 - - up to 140 -
Rated Voltage
Ue = 900 VDC
Rated Operational Current [A] 1200 100 1200 100 - up to 1200 up to 300 up to 300 - - up to 3000 -
Max Breaking Current [A] 2000 160 2000 160 - up to 2000 up to 500 up to 500 - - - -
Resistance [Ohm] - - - - 10 ÷ 150 - - - 10 ÷ 150 10 ÷ 150 - -
Rated Voltage
Ue = 1800 VDC
Rated Operational Current [A] 600 50 600 50 - up to 1000 up to 150 up to 150 - - up to 3000 -
Max Breaking Current [A] 1000 80 1000 80 - up to 1800 up to 250 up to 250 - - - -
Resistance [Ohm] - - - - 40 ÷ 150 - - - 40 ÷ 150 40 ÷ 150 - -
Rated Voltage
Ue = 3600 VDC
Rated Operational Current [A] - - - - - up to 750 up to 110 up to 110 - - up to 3000 -
Max Breaking Current [A] - - - - - up to 1500 up to 125 up to 125 - - - -
Resistance [Ohm] - - - - - - - 40 ÷ 150 40 ÷ 150 - -
Current
measurent
range
(up to)
[A] - - - up to 2000
Dimensions Length L [mm] 400 414 According selected configuration
Width W [mm] 146 160 According selected configuration
Height H [mm] 315 380 According selected configuration